| Installing the Switch
Mounting
– 40 –
MOUNTING
The switch can be mounted in a standard 19-inch equipment rack, on a desktop
or shelf, or on a wall. Mounting instructions for each type of site follow.
RACK MOUNTING
Before rack mounting the switch, pay particular attention to the following
factors:
Temperature: Since the temperature within a rack assembly may be higher
than the ambient room temperature, check that the rack-environment
temperature is within the specified operating temperature range. (See
page 65.)
Mechanical Loading: Do not place any equipment on top of a rack-mounted
unit.
Circuit Overloading: Be sure that the supply circuit to the rack assembly is
not overloaded.
Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than direct
connections to the mains.
Figure 11: Grounding
Terminate the wire at an
earthed grounding point.
Attach an insulated grounding
wire, with a metal screw, to
the marked grounding point.
1.
2.